• For Liquid and Gas flow measurements.
Pipe sizes from: 1/2”(13MM) to 2-1/2"(64MM)
• Integral Transmitter Mount 3 or 5 valve manifold
(IT3V-Option)
• Mass Flow Measurement with dynamic process
compensation for pressure, temperature and DP with
multivariable transmitter
• End connections:
- Threaded and Flanged Type
(150#, 300#, 600#, & 900#) or Higher Ratings
• Low pressure losses (High energy savings),
low pumping costs (1/3 of orifice plate)
• Design Standards: ASME/MFC-3M, ISO-5167, ANSI B31.1 and B31.3
• Materials: Standard 316SS
Others: Per request |
Accuracy:
±0.75% Of Rate – uncalibrated
±0.5% Of Rate – calibrated |
Repeatability:
±0.1% of rate (Over entire flow range) |
Process Temperature:
Up to 300°F (150°C) |
Pressure Rating:
Up to 800psi (55Bar) |
Minimum Reynolds Number:
50,000< Rd<1,000,000 |
Maximumt Pressure Loss:
5 to 10% of DP (depends on pipe size
and Beta ratio) |
Turn Down Ratio (TDR):
Typical 6 to 1 (higher with Multivariable
transmitters) |
Discharge Coefficient:
Very stable - Dependent on Beta Ratio and pipe size |
Maximum Viscosity:
50 CP (CentiPoise) |
|