• Precise "Wedgebar"angle for optimum accuracy and high
turn-down ratio (TDR)
• Suitable for pipes and ducts from 2"(50mm) to
72”(1800mm)
• Integral Transmitter Mount 3 or 5 valve manifold (IT3V)
• Mass Flow Measurement with dynamicprocess
compensation for pressure, temperature, and DP with
Multivariable transmitter
• Integral RTD for process temperature measurements
• Very low pressure losses (High energy savings)
• Low installation costs (1/3 the cost of MAG or Venturi
meters)
• Fixed and Hot-Tap models
• Materials:
- 316/316L Stainless Steel (Standard)
- Others: Monel, Hastelloy, Duplex SS, etc |
Accuracy:
±1% of
rate - uncalibrated
±0.5% of rate - calibrated with
transmitter |
Repeatability:
±0.1%
of rate |
Process Temperature:
Up to 2000°F (1100°C) |
Pressure Rating:
Up to 3000psi (20,000kPa) |
Minimum Reynolds Number:
50,000 Rd |
Maximum Pressure Loss (PPL):
5% of DP-MAX |
Turn Down Ratio (TDR):
10 to 1 and higher with stacked
transmitters |
Maximum Viscosity:
100 CP- CentiPoise (MPAS) |
|